Fire extinguisher inspection, testing & maintenance in Portland, OR

Fire extinguishers are a first line of defense in any commercial, industrial, or multi-family building — and Oregon law requires they be professionally inspected annually per NFPA 10. PDX Fire Protection provides certified fire extinguisher inspection, 6-year maintenance, hydrostatic testing, recharging, and replacement throughout Portland, OR and across Oregon and Washington.

Request a quote

NFPA 10 compliant service for commercial properties across Oregon & Washington

View All Services

NICET Certified

All Technicians

24/7

Emergency response

AHJ Reporting

Included with every job

OR & WA

Licensed service area

What We Do

Fire extinguisher services we provide

Every service performed by ICC-certified technicians in accordance with NFPA 10 standards.

Per NFPA 10, all portable fire extinguishers require a professional annual inspection to verify they’re accessible, charged, and ready to use. We tag each unit, document findings, and flag anything that needs attention.

  • Visual and mechanical condition inspection
  • Pressure gauge and pull pin verification
  • Tamper seal and label checks
  • Mounting and accessibility inspection
  • NFPA 10 compliant inspection tags on every unit

Every six years, stored-pressure extinguishers require internal maintenance — disassembly, internal inspection, and recharging if needed. We perform 6-year maintenance per NFPA 10 and document service for your records.

  • Internal disassembly and inspection
  • O-ring and valve component replacement
  • Recharging to manufacturer’s specifications
  • Updated maintenance collar and service tag

If an extinguisher fails inspection, is due for replacement, or has been discharged, we provide same-visit replacement — so you leave the inspection with every unit in compliance.

Applicable Standards

NFPA 10 • Oregon Fire Code • Washington State Fire Code

Portable fire extinguishers in Oregon and Washington must comply with NFPA 10 — the Standard for Portable Fire Extinguishers. Your local AHJ enforces these requirements and may request service documentation during property inspections.

Inspection Frequency
Visual inspectionMonthly
Full evaluationAnnually

Schedule a fire extinguisher inspection

Annual inspection, 6-year service, or hydrostatic testing in Portland, OR.

Systems We Service

Fire sprinkler systems we service

Our technicians are trained on all commercial fire sprinkler systems used in Oregon and Washington properties.

  • ABC dry chemical

    Most common; covers ordinary combustibles, flammable liquids, and electrical fires

  • CO₂ extinguishers

    Ideal for data centers, labs, and electrical equipment

  • Class K wet chemical

    Required in commercial kitchens for cooking oil fires

  • Class D dry powder

    For combustible metals in industrial settings

  • Clean agent extinguishers

    For sensitive equipment and electronics

  • Water and water mist

    For Class A ordinary combustible fires

Compliance

NFPA 10 compliance for fire extinguishers in Oregon & Washington

Fire sprinkler systems in Oregon and Washington must comply withPortable fire extinguishers in Oregon and Washington must be inspected, maintained, and tested in accordance with NFPA 10 — the Standard for Portable Fire Extinguishers. Oregon and Washington fire codes adopt NFPA 10 by reference, meaning your local Authority Having Jurisdiction (AHJ) enforces its requirements directly. PDX Fire Protection performs all services to NFPA 10 standards and provides documentation for your AHJ and insurance records.

NFPA 10

Standard for Portable Fire Extinguishers — governs inspection, maintenance, recharging, and hydrostatic testing intervals for all portable extinguisher types

Oregon Fire Code

Adopts NFPA 10 by reference — enforced by your local AHJ for all commercial, industrial, and multi-family occupancies in Oregon

Washington State Fire Code

Adopts NFPA 10 by reference — enforced by local fire marshals across Washington for all regulated occupancies

ORS 479 / WAC 212

Oregon and Washington statutes governing fire protection equipment maintenance requirements for commercial property owners and building managers

Why Choose Us

Every extinguisher compliant. Every visit.

  • All service intervals in one visit
    Annual inspection, 6-year maintenance, and hydrostatic testing are tracked per unit and handled on the same scheduled visit whenever possible. You don’t need to manage separate appointments for separate service types.

  • Same-visit replacement
    Our technicians carry common replacement extinguishers and recharging equipment on every truck. If a unit fails inspection or is due for replacement, we swap it on the spot so you leave fully compliant — no follow-up visit needed.

  • Tagged and documented per NFPA 10
    Every extinguisher receives an NFPA 10 compliant inspection tag after service. We provide a full service report for your property records and your AHJ, including unit locations, service performed, and next service dates.

  • All extinguisher classes
    We service ABC dry chemical, CO₂, Class K wet chemical, Class D dry powder, clean agent, and water mist extinguishers. One vendor for every extinguisher type in your building — no matter the occupancy.

Service Area

Fire extinguisher service area

Based in Clackamas, OR — we serve commercial, industrial, and multi-family properties across the Portland metro and throughout Oregon and Washington.

Northwest Oregon

Portland, OR

Gresham, OR

Hillsboro, OR

Beaverton, OR

Clackamas, OR

Lake Oswego, OR

Greater Oregon

Salem, OR

Eugene, OR

Corvallis, OR

McMinnville, OR

Medford OR

Coos Bay, OR

Southwest Washington

Vancouver, WA

Camas, WA

Battleground, WA

Longview, WA

Woodland, WA

Ridgefield, WA

Greater Washington

Seattle, WA

Spokane, WA

Yakima, WA

Tri-Cities, WA

Olympia, WA

Tacoma, WA

FAQ

Fire extinguisher FAQs — Oregon & Washington

Common questions from property managers and facility directors.

Are fire extinguishers required in commercial buildings in Oregon?

Yes. Oregon requires portable fire extinguishers in most commercial, industrial, and multi-family buildings per NFPA 10 and the Oregon Fire Code. Requirements vary by occupancy type and hazard level — your local AHJ determines specific placement and quantity requirements.

Who is responsible for monthly fire extinguisher inspections?

Under NFPA 10, the building owner or their designated representative is responsible for monthly visual inspections — checking that extinguishers are in place, accessible, and show no obvious damage. Annual professional inspections are a separate requirement handled by a certified technician like PDX Fire Protection.

What is hydrostatic testing for fire extinguishers?

Hydrostatic testing uses water pressure to verify that an extinguisher’s shell can safely hold its working pressure without failure. NFPA 10 requires this test every 12 years for most stored-pressure extinguishers. If a unit fails, it must be condemned and replaced.

What does the 6-year fire extinguisher maintenance involve?

Every six years, stored-pressure dry chemical extinguishers must be emptied, internally inspected, and recharged. This ensures that internal components, O-rings, and valve seats are in good condition and the agent hasn’t caked or settled over time.

Can you replace extinguishers on the same visit as the inspection?

Yes. Our technicians carry common replacement extinguishers and recharging equipment. If a unit needs to be replaced or recharged during the annual inspection, we handle it on the spot so you leave fully compliant.

Related Services

Other fire protection services

One vendor for all your fire protection compliance needs.

Fire pumps

Inspection, testing, and maintenance for all common fire pump types.

Learn More →

Backflow testing

OHA-certified annual testing with report filing to your water authority.

Learn More →

Fire Sprinkler Systems

Inspection, testing, and maintenance for all sprinkler types.

Learn More →